Giant response of microbubble contrast agents oscillation in a high-intensity focused ultrasound field

Authors

  • Emil-Alexandru Brujan
  • Yoichiro Matsumoto

Keywords:

cavitation, microbubble contrast agents, giant oscillations

Abstract

The interaction of microbubble contrast agents (BR14) with high-intensity focused ultrasound is investigated by high-speed photography. The experiments were conducted at an ultrasound frequency of 1.08 MHz with a peak negative pressure of 1.8 MPa. The microbubble oscillations run on a giant response with a long expansion phase followed by a violent collapse. The implications in high-intensity focused ultrasound surgery are also discussed.

References

BEKEREDJIAN, R., GRAYBURN, P.A., SHOHET, R.V., Use of ultrasound contrast agents for gene or drug delivery in cardiovascular medicine, J. Am. Coll. Cardiol., 45, pp. 329–335, 2005.

CHOMAS, J.E., DAYTON, P.A., MAY, D., ALLEN, J., KLIBANOV, A., FERRARA, K., Optical observation of contrast agent destruction, Appl. Phys. Lett., 77, pp. 1056–1058, 2005.

DE JONG, N., FRINKING, P.J.A., BOUKAZ, A., GOORDEN, M., SCHOURMANS, T., JINGPING, X., MASTIK, F., Optical imaging of contrast agent microbubbles in an ultrasound field with a 100 MHz camera, Ultrasound Med. Biol., 26, pp. 487-492, 2000.

BOUKAZ, A., VERSLUIS, M., DE JONG, N., High-speed optical obervations of contrast agent destruction, Ultrasound Med. Biol., 31, pp. 391–399, 2005.

CHOMAS, J.E., DAYTON, P.A., MAY, D., ALLEN, J., KLIBANOV, A., FERRRARA, K., Threshold of fragmentation for ultrasonic contrast agents, J. Biomed. Opt., 6, pp. 141–150, 2001.

BLOCH, S.H., WAN, M., DAYTON, P.A., FERRARA, K.W., Optical observation of lipid- and polymer-shelled ultrasound microbubble contrast agents, Appl. Phys. Lett., 84, pp. 631–633, 2004.

PRENTICE, P., CUSCHIERI, A., DHOLAKIA, K., PRAUSNITZ, M., CAMPBELL, P., Membrane disruption by optically controlled microbubble cavitation, Nature Phys., 1, pp. 107–110, 2005.

HANAJIRI, K., MARUYAMA, T., KANEKO, Y., MITSUI, H., WATANABE, S., SATA, M., NAGAI, R., KASHIMA, T., SHIBAHARA, J., OMATA, M., MATSUMOTO, Y., Microbubble-induced increase in ablation of liver tumors by high-intensity focused ultrasound, Hepatol. Res., 36, pp. 308–314, 2006.

YU, T., FAN, X., XIONG, S., HU, K., WANG, Z., Microbubbles assist goat liver ablation by high intensity focused ultrasound, Eur. Radiol., 16, pp. 1557–1563, 2006.

BRUJAN, E.A., The role of cavitation microjets in the therapeutic applications of ultrasound, Ultrasound Med. Biol., 30, pp. 381–387, 2004.

Published

2013-10-20